Reaction formula: CT≥1.6, ozone demand: Po3=qc X O3. Ozone reactor
size: V=qc/60Xt. ©- the amount of ozone added into the water;
t-time requirement for ozone and water contact reaction;
V-the volume of ozone reactor; qc-the circulating water amount)
Max. working pressure: 250kpa/36psi/2.5bar or 400kpa/58psi/4.0bar.
Max. testing pressure: 400kpa/58psi/4.0bar or 600kpa/86psi/6.0bar.
Max. temperature: 50℃(122F)
The surface is constructed of UV-resistant and non-corrosive fiberglass filament winding.
With non-corrosive internal layer.
The full reaction of water and ozone can greatly improve the sterilization effect.
Model | Diameter(mm) | Water inlet/outlet size(mm) | Flow rate(m3/h) | Volume(m3) |
WL-OZ1532 | 800 | 63 | 18 | 0.63 |
WL-OZ1540 | 1000 | 63 | 33 | 1.12 |
WL-OZ1548 | 1200 | 90 | 45 | 1.53 |
WL-OZ2032 | 800 | 63 | 26 | 0.88 |
WL-OZ2040 | 1000 | 75 | 40 | 1.51 |
WL-OZ2048 | 1200 | 90 | 63 | 2.1 |